Ïðîäóêöèÿ Production
Communication wires
 - low pair-count high-frequency cables for subscriber access digital networks
Wires and cables for protection systems and fire signaling systems
Geophysical wires (weight bearing)
Paired cable for structured cabling systems
Wires for industrial explosive activities
Wires for electric heating of concrete
Customer service
Your questions
  guestbook: to question
map site

Ñõåìà ïðîåçäà

Informsystema,
Ltd

Our address:
344055,
17a, Peskova St. Rostov-on-Don

Phone: 222-09-84
299-50-99
Fax: 290-59-90
290-59-89

E-mail: info@informsystema.com

Wires and cables for protection systems and fire signaling systems

ÍÂÌ | ÍÏ | ÌÊÑ 2(4, 6, 8, 10)õ0,5 | ÌÊÑ 2(4, 6, 8, 10)õ0,4 | ÌÊÃÑ 2(4, 6, 8, 10)õ0,12 | ÌÊÃÑ 2(4, 6, 8, 10)õ0,22
Assembly wires with plastic insulation
Signaling cables with copper single-wire core, insulation and PVC sheath
Flexible signaling cables with copper multiple-wire cores, insulation and PVC sheath (analog of "SQR" and "Alarm")
Assembly wires with plastic insulation
ÍÂÌ | ÍÏ  
   

CLASS OF A CORE "1"

ÍÂÌ, ÍÏ

CLASS OF A CORE "4"

ÍÂÌ, ÍÏ
   
DESIGN FEATURES
1. At customer’s request we produce wires of the same construction but having other parameters and made of other materials.
TECHNICAL CONDITIONS
GOST 17515-72 (state standard)
 
BASIC PERFORMANCES
UNITS
ÍÂÌ-0,08
ÍÂÌ-0,2
ÍÏ-0,2
ÍÂÌ-0,2
ÍÂÌ-0,35

CLASS OF A CORE

 

 

1
1
1
4
4
Number of cores in a wire
pcs.
1
1
1
7
7
Nominal cross-section of a core
mm2
0,08
0,2
0,2
0,2
0,35
Diameter of isolated wires in a core
|d|
pcs.
0,32
0,52
0,52
0,2
0,25
Nominal thickness of insulation
|s|
mm
0,35
0,35
0,35
0,35
0,35
External size of a wire
|D|
mm
0,7 - 1,2
0,9 - 1,5
0,9 - 1,5
1,0 - 1,5
1,0 - 1,5
Electrical resistance
T=20°Ñ
Ohm/km
Wire insulation resistance
MOhm/km
Insulation material
Flexible PVC
HDPE
Flexible PVC
Rated weight of 1 km of cable  
êã
1,69 3,15 2,84 3,47 5,13
up
Copper single-wire core signaling cable, insulation and PVC sheath
ÌÊÑ 2(4, 6, 8, 10)õ0,5 | ÌÊÑ 2(4, 6, 8, 10)õ0,4
   


ÌÊÑ 2õ0,4

 

DESIGN FEATURES
1. Conductors are twisted and have different color.
2. Cables can be used in various temperature conditions (from ¥ 40À to + 50ÀC).
3. Assembling should be carried out when the temperature is not lower than 0À.
4. Service life of these cables is«15 years.

TECHNICAL CONDITIONS
TU 3581-003-12154334-2001 (factory standard)


ÌÊÑ 8õ0,4
 
BASIC PERFORMANCES

UNITS

ÌÊÑ 2(4,6,8,10)õ0,4
ÌÊÑ 2(4,6,8,10)õ0,5

Number of cores in a wire

 

pcs.

2
4
6
8
10
2
4
6
8
10
Nominal cross-section of a core

 

mm2
0,12
0,2
Diameter of isolated wires in a core
|d1|
mm
0,4
0,5
Number of isolated wires in a core
pcs.
1
Electric resistance of a core
T=20°Ñ
Ohm/km
148
95
Resistance of insulation
MOhm/km
0,5
Nominal thickness of insulation
|s|
mm
0,3 - 0,15
Nominal thickness of a sheath
|S|
mm
0,5 - 0,1
External diameter of an insulated core
|d2|
mm
1,2
Nominal external diameter of a cable
|D|
mm
3,0
3,4
4,0
4,2
5,0
3,2
3,7
4,3
4,6
5,4
Rated weight of 1 km of cable
kg
9,4
14,3
19,6
24,1
29,9
11,3
18,0
24,9
31,1
38,4
 
up
Flexible signaling cables with copper multiple-wire cores, insulation and PVC sheath (analog of "SQR" and "Alarm")
ÌÊÃÑ 2(4, 6, 8, 10)õ0,12 | ÌÊÃÑ 2(4, 6, 8, 10)õ0,22
 

ÌÊÃÑ 4õ0,12

 

 

DESIGN FEATURES
1. Conductors are twisted and have different color.
2. Cables can be used in various temperature conditions (from ¥ 40À to + 50ÀC ).
3. Assembling should be carried out when the temperature is not lower than 0À.«
4. Service life of these cables is«15 years.

TECHNICAL CONDITIONS
TU 3581-003-12154334-2001 (factory standard)


ÌÊÃÑ 8õ0,4
 
BASIC PERFORMANCES

UNITS

ÌÊÃÑ 2(4,6,8,10)õ0,12
ÌÊÃÑ 2(4,6,8,10)õ0,22

Number of cores in a wire

 

pcs.

2
4
6
8
10
2
4
6
8
10
Nominal cross-section of a core

 

mm2
0,12
0,22
Diameter of isolated wires in a core
|d1|
mm
0,15
0,2
Number of isolated wires in a core
pcs.
7
Electric resistance of a core
T=20°Ñ
Ohm/km
165
95
Resistance of insulation
MOhm/km
0,5
Nominal thickness of insulation
|s|
mm
0,3 - 0,15
Nominal thickness of a sheath
|S|
mm
0,5 - 0,1
External diameter of an insulated core
|d2|
mm
1,2
Nominal external diameter of a cable
|D|
mm
3,1
3,4
4,2
4,4
5,2
3,4
3,9
4,6
4,9
5,8
Rated weight of 1 km of cable
kg
9,6
14,6
20,1
24,6
30,5
12,1
19,0
26,4
32,9
40,7
 

up
 
 
Main | Production | Price | About our company | Contacts | Guestbook | Íà ðóññêèé