Main Production Price About our company Contacts Guestbook

Ïðîäóêöèÿ Production
Communication wires
 - low pair-count high-frequency cables for subscriber access digital networks
Wires and cables for protection systems and fire signaling systems
Geophysical wires (weight bearing)
Paired cable for structured cabling systems
Wires for industrial explosive activities
Wires for electric heating of concrete
Customer service
Your questions
  guestbook: to question
map site

Ñõåìà ïðîåçäà

Informsystema,
Ltd

Our address:
344055,
17a, Peskova St. Rostov-on-Don

Phone: 222-09-84
299-50-99
Fax: 290-59-90
290-59-89

E-mail: info@informsystema.com

PAIRED CABLE FOR STRUCTURED
CABLING SYSTEMS

ÊÑÂ 1õ2õ0,51 | ÊÑÂ 2õ2õ0,51 | ÊÑÂ 4õ2õ0,51
Single-pair telemetric wire
Twin-pair telemetric wire
Cat. 5 unshielded cable
 Single-pair telemetric wire
ÊÑÂ5 1õ2õ0,51  
   
 

ÊÑÂ 1õ2õ0,52

   
APPLICATION
Transmission of telemetric signals in the 1 MHz to 100 MHz frequency range.
SPECIFICATIONS
TU 3574-005-2354334-2005
 

 CABLE STRUCTURE

Conductor diameter 0.51mm (AWG 24) bare copper wire
Conductor insulation HPLDPE
Insulated conductor diameter 0.92mm
Outer sheath PVC*
Wire outer diameter abt. 3.2mm
* Cables can also be supplied with PE sheath (for outdoor cabling), or LSZH sheath (for indoor cabling where strict fire safety requirements are applicable (low smoke, zero halogen)

 BASIC CHARACTERISTICS

Circuit resistance 17.7 Ohms /100m
Wave impedance 100±15 Ohms
Mutual capacitance 5 nF/100m
NVP 69%


Frequency, MHz
1
4
10,0
16
20,0
31,25
62,5
100
125
Operative attenuation, dB/100m
2,0
4,1
6,5
8,3
9,3
11,7
17,0
22
24,9
ââåðõ

 Twin-pair telemetric wire
ÊÑÂ5 2õ2õ0,51  
   

ÊÑÂ 2õ2õ0,52

   
APPLICATION
Transmission of telemetric signals in the 1 MHz to 100 MHz frequency range.
SPECIFICATIONS
TU 3574-005-12154334-2005
   
 CABLE STRUCTURE
Conductor diameter 0.51mm (AWG 24) Bare copper wire
Conductor insulation HPLDPE
Insulated conductor diameter 0.92mm
Outer sheath PVC*
Wire outer size (3.2õ5.6)mm
* Cables can also be supplied with PE sheath (for outdoor cabling), or LSZH sheath (for indoor cabling where strict fire safety requirements are applicable (low smoke, zero halogen)

 BASIC CHARACTERISTICS
Circuit resistance 17.7 Ohms/100m
Wave impedance 100±15 Ohms
Mutual capacitance not more than 5.2 nF/100m
NVP 69%

Frequency, MHz
1
4
10,0
16
20,0
31,25
62,5
100
125
Operative attenuation, dB/100m
2,0
4,1
6,5
8,3
9,3
11,7
17,0
22
24,9
NEXT, dB
65,3
56,3
50,3
47,2
45,8
42,9
38,4
35,3
31
ACR, dB
63,8
52,2
43,8
39,0
36,5
31,2
21,4
13,3
10,0
ââåðõ                  

 Cat. 5 unshielded cable
ÊÑÂ5 4õ2õ0,51  
   
 

ÊÑÂ 4õ2õ0,52

   
ÏÐÈÌÅÍÅÍÈÅ
Designed for use in Cat. 5 and Cat. 5e structured cabling systems, and as the last mile cable
SPECIFICATIONS
TU 3574-005-12154334-2005
   
 CABLE STRUCTURE
Conductor diameter 0.51mm (AWG 24) Bare copper wire
Conductor insulation HPLDPE
Insulated conductor diameter 0.92mm
Outer sheath PVC*
Wire outer size abt. 5.6mm
* Cables can also be supplied with PE sheath (for outdoor cabling), or LSZH sheath (for indoor cabling where strict fire safety requirements are applicable (low smoke, zero halogen)

 BASIC CHARACTERISTICS
Circuit resistance 17.7 Ohms/100m
Wave impedance 100±15 Ohms
Mutual capacitance 5.0 nF/100m
NVP 69%
ââåðõ


Gauge readings (cable analyzer TLUUE DSP-4000)

ÊÑÏ 5 1 õ 2 õ 0,52 ÊÑÏ 5 2 õ 2 õ 0,52 ÊÑÏ 5 4 õ 2 õ 0,52
0,1 ÊÑÏ 5 1 õ 2 õ 0,52
2 190
  7,5
0,1 ÊÑÏ 5 2 õ 2 õ 0,52
3 580
  13,2
0,1 ÊÑÏ 5 4 õ 2 õ 0,52
6 290
  20,5
* PE insulation and sheath
 
Main | Production | Price | About our company | Contacts | Guestbook | Íà ðóññêèé

© 2004 Informsystema, Ltd. All rights reserved.

Address: 344055, Peskova St. 17a, Rostov-on-Don, Russia. Ph.: (863) 222-09-84, 299-50-99 | Fax: 290-59-90, 290-59-89 | E-mail: info@informsystema.com

The site is created by ArtCapital studio.