PAIRED
CABLE FOR STRUCTURED
CABLING SYSTEMS
|
 |
|
|
Single-pair
telemetric wire |
| ÊÑÂ5 1õ2õ0,51 |
|
| |
|
| |
ÊÑÂ 1õ2õ0,52

|
| |
|
APPLICATION
Transmission of telemetric signals
in the 1 MHz to 100 MHz frequency
range.
|
SPECIFICATIONS
TU 3574-005-2354334-2005 |
|
| |
|
CABLE
STRUCTURE
|
| Conductor
diameter |
0.51mm (AWG
24) bare copper wire |
| Conductor insulation |
HPLDPE |
| Insulated
conductor diameter |
0.92mm |
| Outer sheath |
PVC* |
| Wire
outer diameter |
abt.
3.2mm |
*
Cables can also be supplied with PE
sheath (for outdoor cabling), or LSZH
sheath (for indoor cabling where strict
fire safety requirements are applicable
(low smoke, zero halogen)
|
BASIC
CHARACTERISTICS
|
| Circuit
resistance |
17.7
Ohms /100m |
| Wave
impedance |
100±15
Ohms |
| Mutual
capacitance |
5
nF/100m |
| NVP |
69% |
Frequency,
MHz
|
1
|
4
|
10,0
|
16
|
20,0
|
31,25
|
62,5
|
100
|
125
|
| Operative
attenuation, dB/100m |
2,0
|
4,1
|
6,5
|
8,3
|
9,3
|
11,7
|
17,0
|
22
|
24,9
|
|
| Twin-pair
telemetric wire |
| ÊÑÂ5 2õ2õ0,51 |
|
| |
|
|
ÊÑÂ 2õ2õ0,52
|
| |
|
APPLICATION
Transmission of telemetric signals
in the 1 MHz to 100 MHz frequency
range. |
SPECIFICATIONS
TU 3574-005-12154334-2005 |
| |
|
|
CABLE
STRUCTURE
|
| Conductor
diameter |
0.51mm
(AWG 24) Bare copper wire |
| Conductor
insulation |
HPLDPE |
| Insulated
conductor diameter |
0.92mm |
| Outer
sheath |
PVC* |
| Wire
outer size |
(3.2õ5.6)mm |
*
Cables can also be supplied with
PE sheath (for outdoor cabling),
or LSZH sheath (for indoor cabling
where strict fire safety requirements
are applicable (low smoke, zero
halogen)
|
BASIC
CHARACTERISTICS
|
| Circuit
resistance |
17.7
Ohms/100m |
| Wave impedance |
100±15 Ohms |
| Mutual
capacitance |
not
more than 5.2 nF/100m |
| NVP |
69% |
| Frequency,
MHz |
1
|
4
|
10,0
|
16
|
20,0
|
31,25
|
62,5
|
100
|
125
|
| Operative
attenuation, dB/100m |
2,0
|
4,1
|
6,5
|
8,3
|
9,3
|
11,7
|
17,0
|
22
|
24,9
|
| NEXT,
dB |
65,3
|
56,3
|
50,3
|
47,2
|
45,8
|
42,9
|
38,4
|
35,3
|
31
|
| ACR, dB |
63,8
|
52,2
|
43,8
|
39,0
|
36,5
|
31,2
|
21,4
|
13,3
|
10,0
|
 |
|
|
|
|
|
|
|
|
|
|
|
| Cat.
5 unshielded cable |
| ÊÑÂ5
4õ2õ0,51 |
|
|
|
|
| |
ÊÑÂ 4õ2õ0,52

|
| |
|
ÏÐÈÌÅÍÅÍÈÅ
Designed for use in Cat. 5
and Cat. 5e structured cabling
systems, and as the last mile
cable |
SPECIFICATIONS
TU 3574-005-12154334-2005 |
| |
|
|
CABLE
STRUCTURE
|
| Conductor
diameter |
0.51mm
(AWG 24) Bare copper wire |
| Conductor
insulation |
HPLDPE |
| Insulated
conductor diameter |
0.92mm |
| Outer
sheath |
PVC* |
| Wire
outer size |
abt. 5.6mm |
* Cables
can also be supplied with PE sheath
(for outdoor cabling), or LSZH
sheath (for indoor cabling where
strict fire safety requirements
are applicable (low smoke, zero
halogen)
|
BASIC
CHARACTERISTICS
|
| Circuit
resistance |
17.7
Ohms/100m |
| Wave impedance |
100±15 Ohms |
| Mutual
capacitance |
5.0
nF/100m |
| NVP |
69% |
|
 |
Gauge readings (cable analyzer
TLUUE DSP-4000)
|
| ÊÑÏ
5 1 õ 2 õ 0,52 ÊÑÏ 5 2 õ 2 õ 0,52
ÊÑÏ 5 4 õ 2 õ 0,52 |
| 0,1 |
ÊÑÏ 5 1 õ 2 õ 0,52 |
2 190
|
|
7,5 |
| 0,1 |
ÊÑÏ
5 2 õ 2 õ 0,52 |
3 580
|
|
13,2 |
| 0,1 |
ÊÑÏ 5 4 õ 2 õ 0,52 |
6 290
|
|
20,5 |
| * PE insulation
and sheath |
|
|
|
|
|
| |
|
|